精品久久久久久综合网-精品久久久久久中文字幕一区-精品久久久久久中文字幕2017-精品久久久久久中文-精品久久久久久影院免费-精品久久久久久免费影院

Technical service

Techcon TS5540 spray Valve Use Guide - Provided by Yapude

Release Date:2017-08-09
Techcon TS5540 spray ValveThe fluid tank and cylinder are made of FDA compliant 303 stainless steel.TS5540 spray valveOnline replaceable Delrin® The sealing ring made of material ensures complete sealing of the valve core and also improves its service life.TS5540 spray valveThe compact structure and easy to install threaded holes make it convenient to integrate the valve body into automation equipment.The use guide of TS5540 spray valve, compiled by Techcon's high-quality agent Shenzhen Aptech, can be summarized as follows:
2.JPG

catalogue

1. security information

2. description

3. function

4. Valve connection

5. Operating instructions

6. Troubleshooting

7. Maintenance and Cleaning

8. Spare parts and accessories

9. Limited Warranty

1. security information

1.1 Purpose:

Warning: Using this device in any way other than as described in the User Guide may result in personal injury or property damage. Please make sure to follow the 'User Guide'.

OK InternationalWe are not responsible for any personal injury or property damage caused by non-standard use of the equipment. The following behaviors may result in non-standard applications:

? Replace with devices not recommended in the 'User Guide'

? Use incompatible or damaged replacement parts

? Using unverified and/Or unsafe accessories, auxiliary equipment, and connection materials and methods

1.2 Safety precautions:

Do not exceed the maximum rated power when operating this device/set up

? Operation or cleaning/When repairing equipment, it is necessary to wear appropriate personal protective goggles or protective clothing

Glue may be toxic and/Or hazardous substances. Please carefully read the "Material Safety Data Sheet" and safety precautions

2. description

Size:104.1 x 25.4 mm (4.1” x 1.0”)

Weight:331g (0.73lb)

Liquid inlet:1/8” NPTInternal thread

Air intake:10-32 UNF-2B

Atomized air inlet:10-32 UNF-2B

Liquid pressure: maximum100 psi (6.9 bar)

Starting pressure: minimum70 psi (4.8 bar)

Liquid contact parts:303 Stainless steelDelrin®TheTeflon®

Cylinder material:303 stainless steel

Operating frequency: Exceeding 400 circle/branch

3.function
3.JPG

Project Number

explain

1

Stroke control adjustment knob

2

Valve control inlet

3

Liquid inlet

4

Removable spray cap

5

Atomized air inlet


4.
Valve connection
4.JPG

Project Number

explain

1

From air source

2

Gas filter (optional)

3

Constant airflow

4

Valve air hose (provided)

5

Atomizing air hose (provided)

6

Liquid feed hose (optional)

7

Liquid storage container(TS1258 -Purchase)

8

Valve controller(TS500R -Purchase)


5.
Operating instructions

1.Set the valve air pressure of the valve controller to70 psi (4.8 bar).

2.Set the atomizing air pressure of the valve controller according to the viscosity of the spray liquid.

3.The liquid pressure of the liquid reservoir is set according to the viscosity of the spray liquid; Please do not exceed100 psi (6.9bar).

4. Place the waste bin under the valve nozzle and clean the valve until the liquid flows out steadily.

The coverage of spray is determined by the following factors:

? Stroke control adjustment - Clockwise rotation of the stroke control knob can reduce the liquid flow rate, while counterclockwise rotation will increase the liquid flow rate. Do not let the knob exceed the "line mark" on the knob seat.

The starting length set by the valve controller ("valve open" time)

? Liquid storage pressure

? Liquid viscosity

? Distance between nozzle and spray surface

6. Troubleshooting

fault

Possible reasons

Troubleshooting methods

No liquid flow

Liquid pressure too low

Increase the liquid pressure of the liquid storage device

The operating pressure is too low

Raise the air pressure of the valve controller to70 psi

Valve not working

Check the valve pressure of the valve controller

Liquid solidifies inside the valve chamber

Remove the valve and thoroughly clean it

Stroke control adjustment does not work

Rotate the stroke control knob counterclockwise (do not exceed the "line mark")

Unstable liquid flow

Unstable liquid pressure

Ensure a constant liquid pressure

The operating pressure of the valve is too low

Raise the valve operating pressure of the valve controller to70 psi

The opening time of the valve is inconsistent

Check the valve controller to ensure it provides stable air pressure output

Gas is trapped in the valve cover

Discharge gas from the valve

After the valve is closed, liquid still flows out and stops after a period of time

Gas is trapped in the liquid shield

Discharge gas from the valve

Spray interval is too short

Increase the spray interval of the valve controller

The liquid flows through the nozzle but does not
Form spray

The atomization pressure is too low

Improve the atomization pressure of the valve controller

Continuous dripping

Nozzle andDelrin®The base is dirty

Thoroughly clean the nozzle and base

Delrin®The base is worn or damaged

Replace worn or damaged parts

Liquid pressure exceeds100 psi

Reduce the liquid pressure in the liquid storage container until the dripping stops

Valve installation error

Remove the valve and reinstall it according to the instructions


7.
Maintenance and Cleaning

Required tools/Materials (one piece each): open-end wrench, retaining ring pliers, soft brushORing grease, wooden pin, andBig head screw(P/N=TSD1113-28); Recommended cleaning agent: isopropanol or similar solvent.

7.1 Thoroughly clean (see figure)3.0
5.JPG

1. Release the liquid pressure from the liquid storage container.

2. Remove the liquid pipeline and valve air hose from the valve.

3. Adjust the stroke control knob(19)Rotate counterclockwise beyond the "line mark" and remove it, and the compression spring will push the knob out.

4. Remove the compression spring(1)And the Mylar washers at both ends(18).

5. Use an open-end wrench to remove the locking cap(8)Then, from the liquid shield(7)Pull out the air cap in the middle(11).

6. Use an open-end wrench to remove the nozzle(9)And gaskets(13); IfOThe ring is damaged, please replace it.

7. Grasp the liquid shield tightly(7)Rotate the cylinder counterclockwise/Needle assembly(2). After fully unscrewing, pull these two valve components straight apart to separate them.

8. Dip the soft brush in isopropanol and clean the liquid cover(7)Needles/Piston assembly(17)And the nozzle(9).

9. If the valve leaks, please use a large head screw(TSD1113-28)Remove the base(10)And replace the base with a new one; see also7.4 Instructions in section "Replacing the Base".

10. Turn the nozzle(9), gasket(13)Air cap(11)And the locking cap(8)Reinstall the liquid shield(7)In the middle.

11. Lubricate with greaseORing shaped(6)Then move the cylinder/Needle assembly(2)Reinstall the liquid shield(7).

12. First, place a Mylar washer on the needle/Piston assembly(17)Next, place another McLaren washer and compression spring into the stroke control adjustment knob in sequence(18)In this way, the compression spring can be installed(1).

13. Adjust the stroke control knob(19)Rotate clockwise fully into the knob base, then counterclockwise to the desired position, but do not exceed the "line mark" on the base.

7.2 Needle Replacement/Piston assembly and sealing ring (see figure) 3.0

1. Execute the previous section (Section) 7.1 Steps in the section1 - 7.

2. IfORing shaped(6)Damaged, please replace it.

3. From the liquid shield(7)Remove the cup-shaped sealing ring(14).

4. Use retaining ring pliers to remove the first positioning ring(3).

5. Insert the needle/Piston assembly(17)From cylinder(2)Pull it straight out.

6. Use retaining ring pliers to remove the second positioning ring(15).

7. Remove the nylon gasket(16)andORing shaped(5); Replace damaged parts.

8. ReinstallORing shaped(5)Nylon gasket(16)And use a positioning ring(15)Fixed.

9. Reinstall the needle/Piston assembly(17)Using a positioning ring(3)Fixed.

10. Use a soft rod (such as a wooden pin) to seal the cup-shaped seal ring(14)Reinstall the liquid shield(7).

11. Execute the previous section (Section) 7.1 Steps in the section9 - 13.

7.3 Replacement of nozzle and air cap (see figure) 3.0

1. Adjust the stroke control knob(19)Rotate counterclockwise beyond the "line mark" position and remove it.

2. Remove the compression spring(1)And the Mylar washers at both ends(18).

3. Use an open-end wrench to remove the locking cap(8)Then, from the liquid shield(7)Pull out the air cap in the middle(11).

4. Use an open-end wrench to remove the original nozzle(9)And gaskets(13).

5. Reinstall the gasket(13)And use an open-end wrench to reinstall the new nozzle(9)Please ensure thatOThe ring is installed on the nozzle; Do not tighten the nozzle too tightly.

6. Install a new air cap(11)Then use the locking cap(8)Fixed.


7.4 Replace the base (see figure) 4.0

1. Insert the large head screw into the nozzle(9)Rotate clockwise until it aligns with the base(10)to be connected.

2. Use "soft claw" pliers to fix the nozzle, and then pull out the large head screw and sealing ring straight out.

3. Reinstall the new base on the head screw, and then insert the head screw into the nozzle in a straight line. To ensure proper alignment of the base, it is recommended to use a hand press to install the base.

展開
xxxxx性| 欧美在线视频第一页| 久久先锋影音av鲁色资源网| 中文字幕免费观看| 色综合色综合色综合色综合色综合| 男人操女人免费网站| 在线欧美日韩精品| 亚洲怡红院在线| 亚洲影视综合| 欧美成人久久久免费播放| 美女视频一区在线观看| 91视频久久久| 亚洲国产精品va在线观看黑人| 午夜爽爽视频| 国产日韩av在线| 99热这里有精品| 亲爱的老师9免费观看全集电视剧| 最新av中文字幕| 日韩国产精品一区二区三区| 中文精品电影| 黄色一级视频免费看| 91精品国产欧美日韩| 久青草国产在线| 一区视频二区视频| 久久久青草婷婷精品综合日韩| 久久久久99精品| 日韩一区二区精品在线观看| 午夜激情在线观看| 中文字幕久久亚洲| 欧美a级大片在线| 性色av蜜臀av色欲av| 一区二区不卡在线视频 午夜欧美不卡在| www.国产在线| 国产精品国产三级国产专区53| 国产欧美日韩一区二区三区四区| 你懂得在线观看| 一本大道久久a久久精品综合| 免费av毛片在线看| 不卡的在线视频| 国产丝袜欧美中文另类| 蜜桃特黄a∨片免费观看| 国产成人亚洲欧美| 日韩成人一区二区| 四虎国产精品成人永久免费影视| 精品久久久久久久久久| 先锋影音资源999| 亚洲五码在线观看视频| 久久影院午夜片一区| 日本高清中文字幕| 日韩精品 欧美| 中文字幕欧美一区| 亚洲尤物在线视频| 黄色一级片播放| 青青久草在线| 国产日韩欧美久久| 在线观看一区不卡| 国产盗摄在线视频网站| 污免费在线观看| 欧美手机在线| 在线成人综合色一区| 国产日韩精品在线播放| 美女诱惑黄网站一区| 色九视频91| 三级a在线观看| 亚洲国产欧美在线成人app | 中文字幕av免费观看| 国产精品一区二区久久精品 | 91香蕉亚洲精品| 美女mm1313爽爽久久久蜜臀| 亚洲精品久久久成人| 国产女主播av| 在线视频国产一区| 欧美经典一区| 国产人妻精品一区二区三区| 国产偷久久久精品专区| 亚洲欧洲美洲综合色网| www在线免费观看| 污污污www精品国产网站| 超碰97人人做人人爱少妇| 麻豆freexxxx性91精品| 欧洲伦理片一区 二区 三区| 在线观看日韩精品视频| 久久久精品一区二区三区| 国产精品a久久久久| 深夜福利网站| 欧美精品色婷婷五月综合| 精品久久久久久久一区二区蜜臀| 国产一区二区三区日韩精品| 国产精品一区二区三区在线免费观看| 久久久99爱| 婷婷久久综合九色综合绿巨人| 久久久久黄色| 国产美女黄色| 一级片免费在线观看视频| 亚洲日韩中文字幕| 青青草伊人久久| 日本福利在线观看| 久久精品视频7| 成人免费毛片在线观看| 日韩成人av在线播放| 亚洲手机在线| jizz在线观看| 国产超碰人人爽人人做人人爱| 法国空姐在线观看免费| 亚洲国产高清高潮精品美女| 美女精品一区二区| 亚洲伦理影院| 尤物视频..com| 免费在线观看av网址| 午夜一区二区三区| 欧美高清视频一二三区| 久久av老司机精品网站导航| 亚洲国产福利| 国产另类图片| 日韩欧美123区| 一级日韩一区在线观看| 亚洲欧美一区二区三区四区| 极品美女销魂一区二区三区| 狂野欧美性猛交xxxxx视频| 久久91亚洲| 男人的天堂一区| 久久久久亚洲精品成人网小说| 黄色av日韩| 久久精品国产福利| 激情六月丁香| 欧美 日韩 国产 成人 在线 91| 美女日批在线观看| 欧美不卡三区| 久久精品青青大伊人av| t66y最新发布地址| 日韩av在线电影观看| 娇妻被老王脔到高潮失禁视频| sihu成人| 久久国产三级精品| 国产美女久久精品| 亚洲大香人伊一本线| 欧美激情第二页| 日本伊人精品一区二区三区介绍 | 日本www在线观看| 亚洲欧美日韩国产成人精品影院| 日本中文字幕在线视频观看| 在线视频网站| 亚洲欧美偷拍另类a∨色屁股| 国产裸体免费无遮挡| av女优在线| 欧美婷婷六月丁香综合色| japanese中文字幕| 激情久久99| 美女视频久久黄| 精品国产99久久久久久宅男i| 精品1区2区3区4区| 国产亚洲精品美女久久久m| 一个色在线视频| 久久精品在线观看| 91制片厂毛片| 国产极品在线观看| 亚洲欧美变态国产另类| 超碰在线观看91| 伊人久久大香线蕉av超碰演员| 狠狠色噜噜狠狠色综合久| 性直播在线观看| 亚洲午夜免费福利视频| 日本aaa视频| 波多野结衣在线一区二区 | 久久综合香蕉| 国产三级免费观看| 亚洲欧美日韩人成在线播放| 中文字幕在线视频一区二区| 忘忧草在线日韩www影院| 亚洲丝袜av一区| 国产美女明星三级做爰| 日韩激情在线观看| 熟女视频一区二区三区| 精品一二三区视频| 精品日韩一区二区三区| av黄色在线播放| 欧美日韩一卡| 亚洲一区二区三区加勒比| 污视频网站在线免费观看| 欧美亚洲一区三区| 鲁丝一区二区三区| 精品国产一区二区三区av片| 2014亚洲精品| 国产美女特级嫩嫩嫩bbb片| 日本韩国一区二区| 国产污视频在线看| 亚洲美女黄色| 国产精品无码电影在线观看| √天堂8在线网| 国产婷婷成人久久av免费高清 | 国产一区二区波多野结衣 | 国产精品夜间视频香蕉| sese在线| 色av综合在线| 国产三级av片| 免费人成黄页网站在线一区二区| 国产极品在线视频| 99re66热这里只有精品4| 奇门遁甲1982国语版免费观看高清 | 久久欧美一区二区|